Drawing No. |
Title |
No. of Sheets |
File Size |
Section 1 - Mainlaying |
WSD 1.1C |
Typical Details of Pipe Trenches |
4 |
183KB |
WSD 1.2E |
Permanent Reinstatement of Pavement (Concrete Carriageway, Concrete Footway and Run-in, Bituminous Pavement, Paving Slab/Block Construction) - with reference to HyD Standard Drawings Nos. H1107, H1109 and H1124 to H1131 |
9 |
481KB |
WSD 1.3E |
Steel Plate over Trenches |
4 |
158KB |
WSD 1.4H |
Typical Details of Thrust Blocks |
4 |
183KB |
WSD 1.5C |
Typical Details of Anchor Block for Buried Pipes Laid on Slope (Nominal Size DN150 and above) |
1 |
56KB |
WSD 1.6D |
Typical Details of Supports for Exposed Pipeworks (Nominal Size DN150 and above) |
7 |
269KB |
WSD 1.7E |
Precast Concrete Units for Valve Chambers |
2 |
101KB |
WSD 1.8E |
Single Air Valve Chamber |
1 |
52KB |
WSD 1.9E |
Double Air Valve Chamber |
1 |
54KB |
WSD 1.10D |
Chamber for Gate Valve not Exceeding DN300 |
1 |
47KB |
WSD 1.11E |
Chamber for Horizontal Gate Valve DN400 and above - General Arrangement (with by-pass pipework) |
7 |
371KB |
WSD 1.12E |
Chamber for Horizontal Gate Valve DN400 and above - R.C. Details |
7 |
234KB |
WSD 1.13F |
Washout Pump Pit - General Arrangement |
4 |
132KB |
WSD 1.14E |
Washout Pump Pit - R.C. Details |
4 |
138KB |
WSD 1.15E |
Inspection Tee Chamber - General Arrangement |
4 |
199KB |
WSD 1.16E |
Inspection Tee Chamber - R.C. Details |
4 |
142KB |
WSD 1.17F |
Typical Arrangement of DN150 Fire Hydrant |
2 |
84KB |
WSD 1.18C |
Fitting Details for Gate Valves not Exceeding DN300 |
1 |
34KB |
WSD 1.19C |
Cast Iron Grating for Pump Sump |
1 |
38KB |
WSD 1.20C |
Leakage Collection System |
3 |
172KB |
WSD 1.21E |
Steel Pipes and Specials |
11 |
360KB |
WSD 1.22C |
Steel Plate Blank Flanges (Nominal Size DN1400 and above) |
1 |
40KB |
WSD 1.23D |
Steel Loose Ring Flanges (Nominal Size DN700 and above) |
1 |
45KB |
WSD 1.24D |
Top Treatment to Cover of Manholes/Valves Chambers in Carriageway and Footway |
2 |
105KB |
WSD 1.25E |
Portable Flowmeter Chamber for Pipe DN800 and above - General Arrangement |
6 |
220KB |
WSD 1.26D |
Portable Flowmeter Chamber for Pipe DN800 and above - R.C. Details |
3 |
111KB |
WSD 1.27C |
Portable Flowmeter Chamber for Pipe DN700 and below - General Arrangement |
3 |
105KB |
WSD 1.28D |
Portable Flowmeter Chamber for Pipe DN700 and below - R.C. Details |
3 |
106KB |
WSD 1.29E |
Mild Steel Cover for Portable Flowmeter Chamber |
2 |
102KB |
WSD 1.30B |
Arrangement of Gate Valve and Stub Pipe for Portable Insertion Flowmeter for Steel Pipe DN800 or above |
1 |
46KB |
WSD 1.31B |
Identification Tapes for Water Mains |
2 |
85KB |
WSD 1.32F |
Waste Detection Meter Chamber |
6 |
214KB |
WSD 1.33F |
District Metering Meter Chamber |
5 |
187KB |
WSD 1.34B |
Painting on Fire Hydrant |
3 |
119KB |
WSD 1.35B |
Dimensions of Flange Bolts |
1 |
33KB |
WSD 1.36C |
Typical Details of Pipe Alignment Marker Post for Cross Country Mains |
2 |
79KB |
WSD 1.37B |
Detectable Warning Tape |
3 |
148KB |
WSD 1.38B |
Leakage Collection Manhole - General Arrangement |
4 |
188KB |
WSD 1.39C |
Leakage Collection Manhole - R.C. Details |
4 |
139KB |
WSD 1.40D |
Typical Buried Thrust Block Dimensions - for DN450 Ductile Iron Pipe or below |
14 |
457KB |
WSD 1.41B |
Electromagnetic Flowmeter Chamber for Pipe Size DN300 or below |
5 |
198KB |
WSD 1.42A |
Electromagnetic Flowmeter Chamber for Pipe Size DN400 or above - General Arrangement |
5 |
191KB |
WSD 1.43A |
Electromagnetic Flowmeter Chamber for Pipe Size DN400 or above - R.C. Details |
6 |
193KB |
WSD 1.44C |
Schematic Service Main Connection |
4 |
288KB |
WSD 1.45A |
Typical Installation Details for Gate Valves in Polyethylene Pipes |
1 |
46KB |
WSD 1.46 |
Chamber for Vertical Gate Valve DN400 and above - General Arrangement (with by-pass pipework) |
7 |
255KB |
WSD 1.47A |
Chamber for Vertical Gate Valve DN400 and above - R.C. Details |
7 |
228KB |
WSD 1.48A |
Multi-purpose Double Air Valve / Multi-purpose Insertion Chamber (Footway) |
3 |
162KB |
WSD 1.49A |
Multi-purpose Double Air Valve / Multi-purpose Insertion Chamber (Carriageway) - General Arrangement |
6 |
253KB |
WSD 1.50A |
Multi-purpose Double Air Valve / Multi-purpose Insertion Chamber (Carriageway) - R.C. Details |
4 |
154KB |
WSD 1.51A |
Multi-purpose Inspection Tee Chamber - General Arrangement |
5 |
228KB |
WSD 1.52A |
Multi-purpose Inspection Tee Chamber - R.C. Details |
4 |
150KB |
WSD 1.53A |
Multi-purpose Insertion Chamber (Carriageway) |
3 |
137KB |
WSD 1.54 |
Details of Cast Iron Round Head Fire Hydrant |
5 |
169KB |
WSD 1.55A |
Swan Neck Fire Hydrant and Cap (Type II) |
1 |
48KB |